Engine Dynamometer Flow and Consumption
Without Recirculation System
  Dynamometer
Consumption
Cooling Column
Consumption
Total Water
Consumption
Model HP GPM LPM GPM LPM GPM LPM
DX31 250 18 69 8 30 26 99
DX32 500 36 138 16 61 52 199
DX33 750 55 207 24 91 79 298
DX34 1000 73 276 32 122 105 398
DX35 1250 91 345 40 152 131 497
DX36 1500 109 414 48 182 157 597
DX37 1750 127 484 56 213 183 696
DX38 2000 145 553 64 243 209 796
DX39 2250 164 622 72 274 236 895
DX3010 2500 182 691 80 304 262 995
DX3011 2750 200 760 88 334 288 1094
DX3012 3000 218 829 96 365 314 1194
DS4010 3500 255 967 112 426 367 1393
DS4011 3850 280 1064 123 468 403 1532
DS4012 4250 305 1161 134 511 440 1671
TD-3100 1000 73 276 32 122 105 398

Engine Dynamometer Flow and Consumption
With Recirculation System1
  Dynamometer
Flow
Cooling Column
Flow
Total Water
Flow
Total Water2
Consumption
Model HP GPM LPM GPM LPM GPM LPM GPM LPM
DX31 250 25 97 10 36 35 133 2 7
DX32 500 51 193 19 72 70 265 3 13
DX33 750 76 290 29 109 105 399 5 20
DX34 1000 102 387 38 145 140 532 7 27
DX35 1250 127 484 48 181 175 665 9 33
DX36 1500 153 580 57 217 210 797 10 40
DX37 1750 178 677 67 253 245 930 12 47
DX38 2000 204 774 76 290 280 1064 14 53
DX39 2250 229 870 86 326 315 1196 16 60
DX3010 2500 255 967 95 362 350 1329 17 66
DX3011 2750 280 1064 105 398 385 1462 19 73
DX3012 3000 305 1161 114 434 419 1595 21 80
DS4010 3500 356 1354 133 507 489 1861 24 93
DS4011 3850 392 1489 147 557 539 2046 27 102
DS4012 4250 428 1625 160 608 588 2233 29 112
TD-3100 1000 102 387 38 145 140 532 7 27

Chassis Dynamometer Flow and Consumption
Without Recirculation System
  Dynamometer
Consumption
Total Water
Consumption
Model HP GPM LPM GPM LPM
CM51S 550 41 156 41 156
CM51FR60 1100 82 312 82 312
TD-36S 550 56 213 56 213
TD-36 1100 112 426 112 426
TD-24S 550 56 213 56 213
TD-24 1100 112 426 112 426

Chassis Dynamometer Flow and Consumption
With Recirculation System1
  Dynamometer
Flow
Total Water2
Consumption
Model HP GPM LPM GPM LPM
CM51S 550 56 213 3 11
CM51FR60 1100 112 426 6 21
TD-36S 550 56 213 3 11
TD-36 1100 112 426 6 21
TD-24S 550 56 213 3 11
TD-24 1100 112 426 6 21

1 Greater water flow is required with a water recirculation system (versus no system) because the allowed water temperature increase is approximately 50° F (versus 70° F with no system).

2 Recirculating systems have a make-up water requirement of 5% of the total water flow. Approximately 2.5% is due to evaporation loss and 2.5% is due to bleed-off.