Questions? Call (414)755-0040

Fuel Measurement Unit (FMU-600, FMU-1000, FMU-2500, FMU-4250)

Fuel Measurement Unit

The Taylor Dynamometer Fuel Measurement Units are gravimetric type systems and require the DynPro Data Acquisition and Control system for operation.


Simply speaking, these systems accurately measure the weight of the fuel in a beaker and calculate the rate of fuel consumption by continuously analyzing the weight of the beaker as the engine draws and returns fuel. The beaker is self-filling and will automatically maintain the minimum and maximum amounts of fuel in the beaker. All units include a chiller to cool the return fuel and maintain a beaker temperature of 100 deg F (38 deg C). In Engine test cells; these units may eliminate the need for a Day Tank.


The Stationary units (standard); include flexible hoses (14ft) for the engine fuel supply and return lines. All other required connections are identified in the following specification by model number.

Specifications:


Dimensions:

38” [965 mm] W

23” [584 mm] D

46” [1168 mm] H


Shipping Weight: 350 lbs. [159 kg]


Available Options:

1. Mobile base

    • Includes flexible hoses (14ft) for all external

connections.

2. Prime pump.

3. Head Pressure Isolation Kit

    • Required when the fuel storage elevation is above the Fuel Measurement system beaker