Taylor's Blow-by Meter is an in-line flowmeter that provides all the advantages of vortex shedding technology in a design that is perfect for rugged applications with minimal space requirements. Taylor's Blow-By Meter offers the best value for your low pressure flow applications.

Measured: Air or low pressure gas

Flow rate measured: See Chart

Operating Temperature: 0° to 200° F (-18° to 93° C)

Accuracy: +/- 2% full scale (1% of reading with Flow Computer)

Repeatability: +/- 0.5% of reading

Input Power: +12 to +24 VDC @ 35 mA

Outputs: 0 to 5 VDC, 0 to 3 VDC or Frequency

Construction: Anodized aluminum

Pressure loss: As low as 0.1" water column (2.54mm); Pressure loss varies with flow rate

Response Time-Analog/Frequency: 300 ms analog/10 ms frequency

Connector: 5 pin

Applications:

  • Emission measurement
  • Air intake
  • Vapor
  • Engine blow-by
  • Exhaust measurement
  • Low pressure industrial measurement

Engine Instrumentation Unit required.

FLOW RATES
Parameter 051020000
Line Size-in.(mm) 3/4" 1"
Range-ACFM 0.7 to 27 1 to 50
Range-m3/hr 1.1 to 43 1.6 to 80

PRODUCT DIMENSIONS
Inches (mm)
Model A B C D E G H I.D. O.D.
1N044105-1 1.83
(46.5)
3.85
(98)
2.593
(65.8)
8.00
(203)
3.778
(96)
1.880
(47.7)
1.250
(31.7)
.750
(19)
.875
(22)
1N044105-2 1.62
(41)
3.85
(98)
2.50
(63.50)
8.00
(203)
3.950
(100)
1.910
(48.5)
1.295
(33)
1.00
(25)
1.125
(28.5)